Skip to main content

Table 5 Power scheduling for 10-generating unit system (10% SR) considering renewable energy in summer

From: A meliorated Harris Hawks optimizer for combinatorial unit commitment problem with photovoltaic applications

Hour Generation schedule of committed units
  GU1 GU2 GU3 GU4 GU5 GU6 GU7 GU8 GU9 GU10
h1 400 150 150 0 0 0 0 0 0 0
h2 450 150 150 0 0 0 0 0 0 0
h3 455 197.5 197.5 0 0 0 0 0 0 0
h4 455 247.5 247.5 0 0 0 0 0 0 0
h5 455 272.5 272.5 0 0 0 0 0 0 0
h6 455 322.5 322.5 0 0 0 0 0 0 0
h7 455 347.5 347.5 0 0 0 0 0 0 0
h8 455 370.225 370.225 0 0 0 0 0 0 0
h9 455 402.165 402.165 0 25 0 0 0 0 0
h10 455 446.33 446.33 0 25 0 0 0 0 0
h11 455 455 455 0 27.93 20 0 0 0 0
h12 455 455 455 0 68.94 20 0 0 0 0
h13 455 424.07 424.07 0 25 20 0 0 0 0
h14 455 382.765 382.765 0 25 0 0 0 0 0
h15 455 350.205 350.205 0 0 0 0 0 0 0
h16 455 273.07 273.07 0 0 0 0 0 0 0
h17 455 253.58 253.58 0 0 0 0 0 0 0
h18 455 305.7 305.7 0 0 0 0 0 0 0
h19 455 362.705 362.705 0 0 0 0 0 0 0
h20 455 394.245 394.245 130 0 20 0 0 0 0
h21 455 347.42 347.42 130 0 20 0 0 0 0
h22 455 247.5 247.5 130 0 20 0 0 0 0
h23 455 315 0 130 0 0 0 0 0 0
h24 455 215 0 130 0 0 0 0 0 0