Skip to main content

Table 4 Temperature data for cells 1 and 2

From: A market definition paradigm equilibrium voltage analysis of ageing and temperature in lithium-ion cells

Temp. data

Equilibrium voltage, Volts (V)

Equilibrium Ah

Cell

Temperature (oC)

Mean

std dev σ

Min

max

Mean

std dev σ

min

Max

1

− 25

3.29520

0.00011

3.29515

3.29546

683.86192

1.30568

682.30239

686.30519

1

− 10

3.27344

0.00013

3.27329

3.27360

82.15118

0.48871

81.62038

82.97814

1

0

3.28754

0.00011

3.28745

3.28775

217.12042

0.70888

216.04117

218.11452

1

10

3.29529

0.00016

3.29515

3.29545

469.97681

0.49789

469.64525

470.70775

1

20

3.30492

0.00012

3.30469

3.30500

448.72524

1.37806

446.47095

451.20646

1

30

3.30587

0.00012

3.30561

3.30592

487.77130

1.22137

485.75978

489.13828

1

40

3.30807

0.00000

3.30807

3.30807

554.31402

0.63751

553.42829

555.39232

1

50

3.30749

0.00010

3.30746

3.30777

579.16334

0.53226

578.07696

579.79858

2

− 25

3.30744

0.00008

3.30715

3.30746

754.11852

0.87570

752.98775

756.15357

2

− 10

3.27744

0.00016

3.27730

3.27761

93.05854

0.57996

92.24315

93.95024

2

0

3.29307

0.00012

3.29300

3.29331

249.82449

0.77423

248.72001

251.13931

2

10

3.29577

0.00000

3.29577

3.29577

537.87547

0.65576

536.80368

538.86946

2

20

3.31057

0.00008

3.31054

3.31085

515.50053

1.77543

512.48505

519.18224

2

30

3.31278

0.00012

3.31270

3.31300

560.87593

2.07754

556.80575

564.76037

2

40

3.31574

0.00009

3.31547

3.31577

639.73498

2.26134

634.74191

644.18320

2

50

3.31594

0.00014

3.31577

3.31608

700.40409

1.90252

697.24664

704.21593