Table 5 Data for validation with Bi-LSTM trained network

From: Fault classification of three phase induction motors using Bi-LSTM networks

Voltages and currents values (Validation data)

Type of classification

VRY

VYB

VBR

IR

IB

IY

 

405.1

405.4

405.6

7.74

7.72

7.73

NO

399.7

400

400.2

9.45

9.43

9.44

OL

443.2

443.4

443.5

7.44

7.45

7.44

OV

347.6

347.8

348.0

8.55

8.54

8.54

UV

407.5

395.9

396.2

8.74

7.99

6.75

VUB

292.1

400.6

368.8

0

16.54

16.54

SP