Skip to main content

Table 3 Training results with LSTM network [25]

From: Fault classification of three phase induction motors using Bi-LSTM networks

 

NO

OL

OV

UV

VUB

SP

NO

0.9988

0.0002

0.0000

0.0004

0.0004

0.0001

NO

0.9959

0.0014

0.0022

0.0000

0.0000

0.0004

NO

0.9989

0.0001

0.0004

0.0001

0.0004

0.0001

NO

0.9971

0.0001

0.0021

0.0001

0.0005

0.0001

NO

0.9419

0.0001

0.0563

0.0000

0.0015

0.0002

OL

0.0005

0.9990

0.0000

0.0004

0.0000

0.0001

OL

0.0002

0.9995

0.0000

0.0002

0.0000

0.0001

OL

0.0000

0.9998

0.0000

0.0001

0.0000

0.0000

OL

0.0000

0.9999

0.0000

0.0001

0.0000

0.0000

OL

0.0000

0.9999

0.0000

0.0000

0.0000

0.0000

OV

0.0001

0.0000

0.9999

0.0000

0.0000

0.0000

OV

0.0001

0.0000

0.9999

0.0000

0.0000

0.0000

OV

0.0000

0.0000

1.0000

0.0000

0.0000

0.0000

OV

0.0000

0.0000

1.0000

0.0000

0.0000

0.0000

OV

0.0001

0.0000

0.9999

0.0000

0.0000

0.0000

UV

0.0009

0.0015

0.0000

0.9968

0.0007

0.0000

UV

0.0006

0.0012

0.0000

0.9976

0.0006

0.0000

UV

0.0004

0.0009

0.0000

0.9982

0.0004

0.0000

UV

0.0002

0.0005

0.0000

0.9989

0.0003

0.0000

UV

0.0002

0.0004

0.0000

0.9992

0.0003

0.0000

VUB

0.0002

0.0000

0.0000

0.0001

0.9997

0.0000

VUB

0.0007

0.0000

0.0000

0.0005

0.9988

0.0000

VUB

0.0001

0.0000

0.0000

0.0002

0.9997

0.0000

VUB

0.0000

0.0000

0.0000

0.0001

0.9999

0.0000

VUB

0.0001

0.0000

0.0000

0.0001

0.9999

0.0000

SP

0.0001

0.0001

0.0001

0.0000

0.0000

0.9998

SP

0.0001

0.0001

0.0001

0.0000

0.0000

0.9998

SP

0.0001

0.0001

0.0001

0.0000

0.0000

0.9997

SP

0.0001

0.0001

0.0000

0.0000

0.0000

0.9998

SP

0.0001

0.0001

0.0000

0.0000

0.0000

0.9998

  1. The bold values represent classifications identified