Time (h) | Generation scheduling of committed units | Power (MW) | Start-up cost | Hourly fuel cost | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
U1 | U2 | U3 | U4 | U5 | U6 | U7 | U8 | U9 | U10 | ||||
1 | 405 | 150 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 555 | 1450 | 11,208 |
2 | 450 | 150 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 601 | 0 | 11,957 |
3 | 455 | 258 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 713 | 170 | 13,914 |
4 | 455 | 367 | 0 | 0 | 25 | 0 | 0 | 0 | 0 | 0 | 847 | 560 | 16,763 |
5 | 455 | 401 | 0 | 0 | 25 | 0 | 0 | 0 | 0 | 0 | 881 | 60 | 17,352 |
6 | 455 | 392 | 0 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1002 | 0 | 20,059 |
7 | 455 | 434 | 0 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1044 | 0 | 20,783 |
8 | 455 | 355 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1095 | 60 | 22,294 |
9 | 455 | 397 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1137 | 750 | 23,039 |
10 | 455 | 455 | 130 | 130 | 49 | 20 | 0 | 0 | 0 | 0 | 1239 | 30 | 25,339 |
11 | 455 | 455 | 130 | 130 | 85 | 20 | 25 | 0 | 0 | 0 | 1300 | 60 | 27,246 |
12 | 455 | 455 | 130 | 130 | 121 | 20 | 25 | 0 | 0 | 0 | 1336 | 0 | 27,995 |
13 | 455 | 455 | 130 | 130 | 44 | 0 | 25 | 0 | 0 | 0 | 1239 | 0 | 25,610 |
14 | 455 | 449 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1189 | 0 | 23,937 |
15 | 455 | 382 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1122 | 60 | 22,772 |
16 | 455 | 206 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 946 | 260 | 19,699 |
17 | 455 | 192 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 932 | 170 | 19,455 |
18 | 455 | 310 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1050 | 0 | 21,515 |
19 | 455 | 402 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1142 | 60 | 23,115 |
20 | 455 | 455 | 130 | 130 | 53 | 0 | 0 | 0 | 0 | 10 | 1233 | 0 | 25,560 |
21 | 455 | 416 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1156 | 0 | 23,374 |
22 | 455 | 436 | 0 | 0 | 25 | 0 | 0 | 0 | 0 | 0 | 916 | 0 | 17,957 |
23 | 455 | 249 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 704 | 0 | 13,754 |
24 | 431 | 150 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 581 | 0 | 11,626 |
Overall Cost of generation = 490,013.6840 |