Skip to main content

Table 7 Generation scheduling for 10-unit system with wind and EV penetration using CSMA

From: An optimal solution to unit commitment problem of realistic integrated power system involving wind and electric vehicles using chaotic slime mould optimizer

Time (h)

Generation scheduling of committed units

Power (MW)

Start-up cost

Hourly fuel cost

U1

U2

U3

U4

U5

U6

U7

U8

U9

U10

1

405

150

0

0

0

0

0

0

0

0

555

1450

11,208

2

450

150

0

0

0

0

0

0

0

0

601

0

11,957

3

455

258

0

0

0

0

0

0

0

0

713

170

13,914

4

455

367

0

0

25

0

0

0

0

0

847

560

16,763

5

455

401

0

0

25

0

0

0

0

0

881

60

17,352

6

455

392

0

130

25

0

0

0

0

0

1002

0

20,059

7

455

434

0

130

25

0

0

0

0

0

1044

0

20,783

8

455

355

130

130

25

0

0

0

0

0

1095

60

22,294

9

455

397

130

130

25

0

0

0

0

0

1137

750

23,039

10

455

455

130

130

49

20

0

0

0

0

1239

30

25,339

11

455

455

130

130

85

20

25

0

0

0

1300

60

27,246

12

455

455

130

130

121

20

25

0

0

0

1336

0

27,995

13

455

455

130

130

44

0

25

0

0

0

1239

0

25,610

14

455

449

130

130

25

0

0

0

0

0

1189

0

23,937

15

455

382

130

130

25

0

0

0

0

0

1122

60

22,772

16

455

206

130

130

25

0

0

0

0

0

946

260

19,699

17

455

192

130

130

25

0

0

0

0

0

932

170

19,455

18

455

310

130

130

25

0

0

0

0

0

1050

0

21,515

19

455

402

130

130

25

0

0

0

0

0

1142

60

23,115

20

455

455

130

130

53

0

0

0

0

10

1233

0

25,560

21

455

416

130

130

25

0

0

0

0

0

1156

0

23,374

22

455

436

0

0

25

0

0

0

0

0

916

0

17,957

23

455

249

0

0

0

0

0

0

0

0

704

0

13,754

24

431

150

0

0

0

0

0

0

0

0

581

0

11,626

Overall Cost of generation = 490,013.6840