Time (h) | Generation scheduling of committed units | Power (MW) | Start-up cost | Hourly fuel cost | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
U1 | U2 | U3 | U4 | U5 | U6 | U7 | U8 | U9 | U10 | ||||
1 | 455 | 245 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 700 | 1620 | 13,683 |
2 | 455 | 295 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 750 | 0 | 14,554 |
3 | 455 | 370 | 0 | 0 | 25 | 0 | 0 | 0 | 0 | 0 | 850 | 560 | 16,809 |
4 | 455 | 455 | 0 | 0 | 40 | 0 | 0 | 0 | 0 | 0 | 950 | 0 | 18,598 |
5 | 455 | 390 | 130 | 0 | 25 | 0 | 0 | 0 | 0 | 0 | 1000 | 0 | 20,051 |
6 | 455 | 360 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1100 | 520 | 22,387 |
7 | 455 | 410 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1150 | 0 | 23,262 |
8 | 455 | 455 | 130 | 130 | 30 | 0 | 0 | 0 | 0 | 0 | 1200 | 170 | 24,150 |
9 | 455 | 455 | 130 | 130 | 85 | 20 | 25 | 0 | 0 | 0 | 1300 | 180 | 27,251 |
10 | 455 | 455 | 130 | 130 | 162 | 33 | 25 | 10 | 0 | 0 | 1400 | 0 | 30,058 |
11 | 455 | 455 | 130 | 130 | 162 | 73 | 25 | 10 | 10 | 0 | 1450 | 60 | 31,916 |
12 | 455 | 455 | 130 | 130 | 162 | 80 | 25 | 43 | 10 | 10 | 1500 | 30 | 33,890 |
13 | 455 | 455 | 130 | 130 | 162 | 33 | 25 | 10 | 0 | 0 | 1400 | 0 | 30,058 |
14 | 455 | 455 | 130 | 130 | 85 | 20 | 25 | 0 | 0 | 0 | 1300 | 0 | 27,251 |
15 | 455 | 455 | 130 | 130 | 30 | 0 | 0 | 0 | 0 | 0 | 1200 | 0 | 24,150 |
16 | 455 | 310 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1050 | 0 | 21,514 |
17 | 455 | 260 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1000 | 120 | 20,642 |
18 | 455 | 360 | 130 | 130 | 25 | 0 | 0 | 0 | 0 | 0 | 1100 | 60 | 22,387 |
19 | 455 | 455 | 130 | 130 | 30 | 0 | 0 | 0 | 0 | 0 | 1200 | 430 | 24,150 |
20 | 455 | 455 | 130 | 130 | 162 | 33 | 25 | 10 | 0 | 0 | 1400 | 30 | 30,058 |
21 | 455 | 455 | 130 | 130 | 85 | 20 | 25 | 0 | 0 | 0 | 1300 | 0 | 27,251 |
22 | 455 | 455 | 0 | 0 | 145 | 20 | 25 | 0 | 0 | 0 | 1100 | 0 | 22,736 |
23 | 455 | 420 | 0 | 0 | 25 | 0 | 0 | 0 | 0 | 0 | 900 | 0 | 17,685 |
24 | 455 | 345 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 800 | 0 | 15,427 |
Overall Cost of generation = 563,698.15824 |