Table 3 Summarization of results and percentage error

From: Voltage and frequency control of standalone wind-driven self-excited reluctance generator using switching capacitors

Compensation Generator voltage Generator current Load current
Short-shunt result
Simulated 175.6 1.04 0.23
Experimental 183 1.1 0.26
Error (%) 4.2 5.4 11.5
Long-shunt result
Simulated 123.5 0.76 0.2
Experimental 139 0.88 0.23
Error (%) 11 13.6 15