Skip to main content

Advertisement

Table 2 Input data of the 5-unit test system

From: Dynamic economic dispatch using hybrid metaheuristics

Unitai ($)bi ($/MWh)ci ($/MW2h)ei ($/h)fi (rad/MW)Pmin (MW)Pmax (MW)UR (MW/h)DR (MW/h)POZs (MW)
U12520.0081000.04210753030[25 30], [55 60]
U2601.80.0031400.04201253030[45 50], [80 90]
U31002.10.00121600.038301754040[60 70], [125 140]
U412020.0011800.037402505050[95 110], [160 180]
U5401.80.00152000.035503005050[85 100], [175 200]