Table 7 Effect of damping on micro-grid with composite load

From: Small signal stability analysis of stand-alone microgrid with composite load

Eigenvalues ζ = 0 ζ = 1 ζ = 10 ζ = 100
Negative 15 15 19 19
Positive 2 0 0 0
Real 19 19 19 21
Complex 1 1 1 0
Zero 4 6 2 2