Table 4 Comparison between the proposed and the traditional connections of the TWSPSEIG at resistive loads

From: Analysis of a proposed connection for the two-winding single-phase self-excited induction generator operating at constant voltage and frequency

RL (Ω)

p.u. speed

Trad

p.u. speed

New

CM

Trad

(µF)

CM

New

(µF)

CA

Trad

(µF)

CA

New

(µF)

VM

Trad

(V)

VM

New

(V)

VA

Trad

(V)

VA

New

(V)

IM

Trad

(A)

IM

New

(A)

IA

Trad

(A)

IA

New

(A)

\( \eta \)

Trad

(%)

\( \eta \)

New

(%)

80

1.032

1.1

52

41

12

6

230

174

328

139

5

4

1

4

82

54

120

1.023

1.064

52

27

9

6

230

157

315

153

4

3

1

3

81

62

180

1.017

1.044

53

22

7

4

230

148

305

160

4

2

1

2

76

66

220

1.0145

1.036

52

18

7

4

230

143

303

164

4

2

1

2

73

60