Skip to main content

Table 4 Control variable limits (p.u.) for different test cases

From: Optimal reactive power dispatch using a novel optimization algorithm

Case no \(V_{g}^{\min }\) \(V_{g}^{\max }\) \(V_{PQ}^{\min }\) \(V_{PQ}^{\max }\) \(T^{\min }\) \(T^{\max }\) \(Q_{c}^{\min }\) \(Q_{c}^{\max }\)
1 0.9 1.1 0.95 1.05 0.95 1.05 -0.12 0.36
2 0.95 1.1 0.95 1.1 0.9 1.1 0 0.36