Table 6 Sensitivity analysis with proposed hybrid DE-PS optimized FOPID controller in parallel AC-DC link

From: Comparative performance analysis of hybrid differential evolution and pattern search technique for frequency control of the electric power system

Parameters

variations

% change

Ts ( 2% band)

Peak overshoot (× 10–3)

Peak undershoot (× 10–3)

ITAE

∆ F1

∆ F2

∆ PTie

∆ F1

∆ F2

∆ PTie

∆ F1

∆ F2

∆ PTie

Nominal

–

3.72

4.03

5.79

0.5

1.1

1.2

− 12.0

− 13.3

− 0.2

0.2156

Loading

conditions

 + 25

3.88

4.05

5.95

0.4

1.0

1.2

− 12.0

− 13.2

− 0.2

0.2800

− 25

3.63

4.70

5.00

0.5

1.1

1.2

− 12.1

− 13.3

− 0.2

0.2667

TG

 + 25

3.82

3.98

5.65

0.7

1.0

1.3

− 12.1

− 13.4

− 0.2

0.2246

− 25

3.64

4.72

5.01

0.4

1.1

1.2

− 11.8

− 13.1

− 0.2

0.2660

TT

 + 25

4.52

4.62

5.03

1.3

1.2

1.3

− 12.3

− 13.5

− 0.2

0.2663

− 25

3.74

4.00

5.08

0.4

1.0

1.2

− 11.6

− 13.0

− 0.2

0.2146

TRH

 + 25

3.89

4.96

5.92

0.3

0.9

1.2

− 12.0

− 13.2

− 0.2

0.2756

− 25

3.06

4.69

5.31

0.7

0.7

1.2

− 12.1

− 13.3

− 0.2

0.2589

TCD

 + 25

3.89

5.04

5.72

0.5

0.9

1.2

− 12.0

− 13.3

− 0.2

0.2925

− 25

3.62

5.11

5.35

0.5

0.9

1.3

− 12.0

− 13.3

− 0.2

0.2797

T12

 + 25

4.03

4.64

4.87

0.4

0.9

1.3

− 12.1

− 13.2

− 0.2

0.2560

− 25

3.85

4.08

5.22

0.6

1.1

1.1

− 11.9

− 13.4

− 0.3

0.2453