Skip to main content

Table 13 Power scheduling for 6-generating unit system considering renewable energy in winter

From: A meliorated Harris Hawks optimizer for combinatorial unit commitment problem with photovoltaic applications

Hour Generation schedule of committed units
GU1 GU2 GU3 GU4 GU5 GU6
h1 166 0 0 0 0 0
h2 154.35294 41.647059 0 0 0 0
h3 181.52941 47.470588 0 0 0 0
h4 196.52466 50.683857 19.79148 0 0 0
h5 200 60.78125 22.61875 0 0 0
h6 200 51.875 20.125 0 0 0
h7 195.52941 50.470589 0 0 0 0
h8 168.35294 44.647059 0 0 0 0
h9 150.58702 40.840077 0 0 0 0
h10 157.44 0 0 0 0 0
h11 140.4 0 0 0 0 0
h12 141.96 0 0 0 0 0
h13 148.01 0 0 0 0 0
h14 168.48 0 0 0 0 0
h15 175.88 0 0 0 0 0
h16 160.44706 42.952941 0 0 0 0
h17 176.51412 46.395882 0 0 0 0
h18 176.32471 46.355294 0 0 0 0
h19 180.72235 47.297647 0 0 0 0
h20 178.08706 46.732941 0 0 0 0
h21 160.94118 43.058824 0 0 0 0
h22 142.82353 39.176471 0 0 0 0
h23 161 0 0 0 0 0
h24 131 0 0 0 0 0