Table 5 Comparison of different algorithms for scenario 5 (Case A: without RES) in 118-bus test system

From: Multi-objective economic operation of modern power system considering weather variability using adaptive cuckoo search algorithm

Item Algorithm
ACSA CSA PSO CSO FPA GOA WOA ALO
Pg,CE (MW) 4814.26 4815.33 4816.42 4817.54 4818.68 4815.43 4816.28 4818.61
Qg,CE (MVAr) 735.64 771.7 807.62 843.43 879.1 793.1 802.43 842.98
CE_Cost($/h) 149,412.94 149,416.68 149,421.01 149,417.58 149,419.38 149,413.62 149,414.72 149,414.23
Ploss (MW) 77.8337 78.2312 78.8231 78.9396 79.0818 78.2741 78.3292 80.3361
VCPIavg 0.0051 0.0052 0.0053 0.0054 0.0055 0.0052 0.0054 0.0054
AVDIavg 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007
OF 149,490.78 149,494.92 149,499.84 149,496.53 149,498.47 149,491.9 149,493.06 149,494.57
Time (s) 1.73 1.92 2.02 1.95 1.88 1.82 1.93 2.04