From: Dynamic investigation of Georges phenomenon related to three-phase wound-rotor induction motor
Rotor connection | Instant of fault | The value of load torque | Gorges phenomenon |
---|---|---|---|
Isolated neutral star | Starting with opening one phase | Up to full load | Occurs |
Opening one phase during normal operation | < 67% of its full load | Does not occur | |
Standard delta connection with external open phase | Starting with opening one phase | Up to full load | Occurs |
Opening one phase during normal operation | < 67% of its full load | Does not occur | |
Standard delta connection with internal open phase | Starting with opening one phase | < 87.5% of its full load | Does not occur |
Opening one phase during normal operation | Up to full load | Does not occur | |
Delta connection with reversed one phase and external open circuit | Starting with opening one phase | Up to full load | Does not occur |
Opening one phase during normal operation | Up to full load | Does not occur |