From: Analysis of a proposed connection for the two-winding single-phase self-excited induction generator operating at constant voltage and frequency

Fig. 8

a Main and auxiliary capacitance versus p.u. speed at a load of 140 Ω and 0.85 power factor, with constant load voltage and frequency, b Main and auxiliary capacitance versus p.u. speed at a load of 240 Ω and 0.75 power factor, with constant load voltage and frequency, c main and auxiliary capacitance versus P.U. speed at a load of 370 Ω and 0.65 power factor, with constant load voltage and frequency